Neha Patil (Editor)

Pulmonary function testing

Updated on
Edit
Like
Comment
Share on FacebookTweet on TwitterShare on LinkedInShare on Reddit
Pulmonary function testing

TLC
  
Total lung capacity: the volume in the lungs at maximal inflation, the sum of VC and RV.

TV
  
Tidal volume: that volume of air moved into or out of the lungs during quiet breathing (TV indicates a subdivision of the lung; when tidal volume is precisely measured, as in gas exchange calculation, the symbol TV or VT is used.)

RV
  
Residual volume: the volume of air remaining in the lungs after a maximal exhalation

ERV
  
Expiratory reserve volume: the maximal volume of air that can be exhaled from the end-expiratory position

IRV
  
Inspiratory reserve volume: the maximal volume that can be inhaled from the end-inspiratory level

IC
  
Inspiratory capacity: the sum of IRV and TV

Pulmonary Function Testing (PFT) is a complete evaluation of the respiratory system including patient history, physical examinations, chest x-ray examinations, arterial blood gas analysis, and tests of pulmonary function. The primary purpose of pulmonary function testing is to identify the severity of pulmonary impairment. Pulmonary function testing has diagnostic and therapeutic roles and helps clinicians answer some general questions about patients with lung disease. PFTs are normally performed by a respiratory therapist.

Contents

Indications

Pulmonary function testing is a diagnostic and management tool used for a variety of reasons, such as:

  • Chronic shortness of breath
  • Asthma
  • Chronic obstructive pulmonary disease
  • Restrictive lung disease
  • Preoperative testing
  • Impairment or disability
  • Pediatric neuromuscular disorders

    Neuromuscular disorders such as Duchenne muscular dystrophy are associated with gradual loss of muscle function over time. Involvement of respiratory muscles results in poor ability to cough and decreased ability to breathe well and leads to collapse of part or all of the lung leading to impaired gas exchange and an overall insufficiency in lung strength. Pulmonary function testing in patients with neuromuscular disorders helps to evaluate the respiratory status of patients at the time of diagnosis, monitor their progress and course, evaluate them for possible surgery, and gives an overall idea of the prognosis.

    Spirometry

    Spirometry includes tests of pulmonary mechanics – measurements of FVC, FEV1, FEF values, forced inspiratory flow rates (FIFs), and MVV. Measuring pulmonary mechanics assesses the ability of the lungs to move large volumes of air quickly through the airways to identify airway obstruction.

    The measurements taken by the spirometry device are used to generate a pneumotachograph that can help to assess lung conditions such as: asthma, pulmonary fibrosis, cystic fibrosis, and chronic obstructive pulmonary disease. Physicians may also use the test results to diagnose bronchial hyperresponsiveness to exercise, cold air, or pharmaceutical agents.

    Complications of spirometry

    Spirometry is a safe procedure; however, there is cause for concern regarding untoward reactions. The value of the test data should be weighed against potential hazards. Some complications have been reported, including pneumothorax, increased intracranial pressure, fainting, chest pain, paroxysmal coughing, nosocomial infections, oxygen desaturation, and bronchospasm.

    Lung volumes

    There are four lung volumes and four lung capacities. A lung capacity consists of two or more lung volumes. The lung volumes are tidal volume (VT), inspiratory reserve volume (IRV), expiratory reserve volume (ERV), and residual volume (RV). The four lung capacities are total lung capacity (TLC), inspiratory capacity (IC), functional residual capacity (FRC) and vital capacity (VC).

    Maximal respiratory pressures

    Measurement of maximal inspiratory and expiratory pressures is indicated whenever there is an unexplained decrease in vital capacity or respiratory muscle weakness is suspected clinically. Maximal inspiratory pressure (MIP) is the maximal pressure that can be produced by the patient trying to inhale through a blocked mouthpiece. Maximal expiratory pressure (MEP) is the maximal pressure measured during forced expiration (with cheeks bulging) through a blocked mouthpiece after a full inhalation. Repeated measurements of MIP and MEP are useful in following the course of patients with neuromuscular disorders.

    Diffusing capacity

    Measurement of the single-breath diffusing capacity for carbon monoxide (DLCO) is a fast and safe tool in the evaluation of both restrictive and obstructive lung disease.

    Oxygen desaturation during exercise

    The six-minute walk test is a good index of physical function and therapeutic response in patients with chronic lung disease, such as COPD or idiopathic pulmonary fibrosis.

    Arterial blood gases

    Arterial blood gases (ABGs) are a helpful measurement in pulmonary function testing in selected patients. The primary role of measuring ABGs in individuals that are healthy and stable is to confirm hypoventilation when it is suspected on the basis of medical history, such as respiratory muscle weakness or advanced COPD.

    ABGs also provide a more detailed assessment of the severity of hypoxemia in patients who have low normal oxyhemoglobin saturation.

    Helium Dilution

    The helium dilution technique for measuring lung volumes uses a closed, rebreathing circuit. This technique is based on the assumptions that a known volume and concentration of helium in air begin in the closed spirometer, that the patient has no helium in their lungs, and that an equilibration of helium can occur between the spirometer and the lungs.

    Nitrogen Washout

    The nitrogen washout technique uses a non-rebreathing open circuit. The technique is based on the assumptions that the nitrogen concentration in the lungs is 78% and in equilibrium with the atmosphere, that the patient inhales 100% oxygen and that the oxygen replaces all of the nitrogen in the lungs.

    Plethysmography

    The plethysmography technique applies Boyle's law and uses measurements of volume and pressure changes to determine lung volume, assuming temperature is constant.

    Interpretation of tests

    Professional societies such as the American Thoracic Society/ European Respiratory Society have published guidelines regarding conduct and interpretation of pulmonary function testing to ensure standardization and uniformity in performance of tests. The interpretation of tests depends on comparing the patients values to published normals from previous studies. Deviation from guidelines can result in false-positive or false negative test results. Mohanka MR et al. recently demonstrated that only a small minority of pulmonary function laboratories followed published guidelines for spirometry, lung volumes and diffusing capacity in 2012. Ref. A survey of practices of pulmonary function interpretation in laboratories in Northeast Ohio Mohanka MR, et al. Chest. 2012;141(4):1040-1046

    Significance

    Changes in lung volumes and capacities are generally consistent with the pattern of impairment. TLC, FRC, and RV increase with obstructive lung diseases and decrease with restrictive impairment.

    References

    Pulmonary function testing Wikipedia