Trisha Shetty (Editor)

New Zealand DSC class locomotive

Updated on
Edit
Like
Comment
Share on FacebookTweet on TwitterShare on LinkedInShare on Reddit
Power type
  
Diesel-electric

UIC class
  
Bo-Bo

Length
  
11.66 m (38 ft 3 in)

Build date
  
1959–1967

Gauge
  
1,067 mm (3 ft 6 in)

New Zealand DSC class locomotive

Builder
  
British Thomson-Houston (18), NZR Hillside Workshops and Addington Workshops (52)

The New Zealand DSC class is a heavy shunting locomotive used throughout New Zealand. The class was built in seven batches, the first 18 locomotives being built by British Thomson-Houston of the United Kingdom, with the remainder being built by New Zealand Railways.

Contents

The class is widely used in both the North and South Islands of New Zealand, mainly for heavy yard shunting, although some members of the class have been used for local mainline shunting services. All members of the class are now fitted with shunters refuges, and most are fitted with remote control capabilities.

Design and entry into service

In the late 1950s, NZR needed a suitable heavy shunting locomotive that produced more power than the existing DS and DSA class locomotives and would be suitable for replacing the BB, C, and WF class steam locomotives. In 1959, an order was placed with British Thompson-Houston in association with the Clayton Equipment Company for eighteen centre-cab shunting engines with a horsepower output of around 420 hp.

The new locomotives, allocated road numbers DSC 400-417, entered service in 1959-60 and were allocated to Auckland and Frankton Junction (Hamilton). For a time in 1962, DSC 402 was dispatched to Picton to shunt the NZR road/rail ferry MV Aramoana until newly constructed Addington DSC 418 arrived to take over, allowing 402 to return north.

The BTH locomotives were powered by two Rolls-Royce C6SFL 210 hp diesel engines connected to BTH generators, which were in turn coupled to four BTH traction motors, one to each axle. They were not entirely without trouble, though, with issues arising with the airbrakes and spare parts for the diesel engines among others. However, once this was resolved, the class settled down to work reliably in their intended role.

Two further orders were placed with the NZR Addington and Hillside Workshops in the 1960s, with production running from 1962 to 1967. The NZR-built locomotives were different in that they were powered by two Leyland UE902 diesel engines producing 210 hp, and had electrical equipment built by Associated Electrical Industries Ltd (AEI), which had purchased BTH earlier. Again there were various troubles, this time more to do with the mechanical components and compatibility on later batches.

Re-engining

In the late 1970s, NZ Rail decided to undertake a re-engining programme for the DSC class. Due to design differences, it would not be possible to use the same type of diesel engine across all locomotives, and so two different types were selected:

  • All BTH locomotives would be repowered with the Rolls-Royce C6TFL diesel engine.
  • All NZR locomotives would be repowered with the Cummins NT855 diesel engine.
  • The process was spread out from the late 1970s into the early 1980s. As part of this, some locomotives were repainted in the International Orange livery but with their pre-TMS numbers instead of the later TMS numbers. As a result of this, the locomotives were equipped with new radiator header tanks which were mounted behind the radiator on top of the engine hoods in a 'north-south' alignment. Later the tanks were relocated to an 'east-west' alignment.

    Fitting shunter's refuges

    In 1989, DSC 2406 was trialled as the first shunting locomotive to be fitted with shunter's refuges at either end of the locomotive. New recessed steps were fitted at either end of the locomotive frames with a vertical hand-rail on the running-board proper. The locomotive's engine hoods were not shortened at the time.

    This modification was successful, but it was noted that the engine hoods were a potential constraint. All further DSC class locomotives equipped with the refuges had their engine hoods shortened by 500mm, necessitating the relocation of the radiator header tanks to their present 'east-west' alignment.

    This modification was subsequently made to all DSG, DSJ, and DH class locomotives as well as DAR 517. None of the BTH-built DSC class locomotives were fitted with these refuges and several NZR-built examples did not receive them either, due to withdrawal before they could be fitted or by dint of being used for other purposes.

    Disposal

    As of March 2017, 40 units have been withdrawn from the railways.

    BTH-builds

    As apart of the program of the New Zealand Railways Corporation to rationalize the locomotive fleet in the late 1980s, all of the British Thomson-Houston built locomotives were withdrawn. All, besides one, were scrapped either at Otahuhu Workshops, or at Hutt Workshops between October 1989 and early 1990.

    DSC 2067 was given a reprieve when it was sold to the NZ Dairy Group (later subsumed into Fonterra) to shunt their Whareroa milk factory. In 2003, the loco was overhauled at the Westfield servicing facility. The overhaul included repairs and a repaint. In 2007, the locomotive was sold to Alliance Group Limited to shunt at their Pukeuri freezing works on the outskirts of Oamaru. In the late 2000s/early 2010s, it was repainted into the Alliance Groups yellow livery, and its two Rolls-Royce engines were replaced with two Cummins engines.

    NZR-builds

    With the rationalization of the locomotive fleet in the late 1980s, three NZR builds were were withdrawn in 1989. Between 1989 and 1990, two units were laid up after being damaged due to accidents. Between 1998 and 2010, 18 units were laid up due to being either, surplus to requirements, due to accident damage or catching fire. Eleven of them were scrapped, while three were returned to service, two were sold to industrial users and another two were preserved. The frame of DSC 2231 was used as a test-bed for overhauled Cummins engines after being withdrawn. In September 2015, DSC 2338 was also laid up and and sent to Hutt Workshops for storage.

    The first unit to be preserved, DSC 2759, was purchased by Ian Welch in August 2002. The loco was moved to Mainline Steams Plimmerton depot. The loco was repainted in Mainline Steams variation of the Tranz Rail Blue livery. It has been named as "Show Pony". The second unit to be preserved, DSC 2584, was purchased by the Waitara Railway Preservation Society in January 2003. In 2011, the locomotive was repainted in their own livery, of dark blue and light yellow.

    Two units were also sold, but this time to industrial users. DSC 2421 was sold to Alliance Group for their freezing works in Lorneville in July 2002. The loco was given a mechanical tidy-up at Hutt Workshops,and was repainted in the companys livery with a grey cab, yellow hoods and thin red chevron stripes on the ends, and is still in service. The other unit, DSC 2257, was sold sometime in 2007 to Ravensdown Fertilizer for their New Plymouth plant. The loco had been on loan to the company for a amount of time before being sold. It was placed into storage due to operational reasons, and has been cheaper to hire one from KiwiRail.

    In August 2016, KiwiRail issued a Request for Quotation (RFQ) via the Government Electronic Tendering Service (GETS) for DSCs 2285, 2338, 2434 and 2680. Following the sale of the four DSCs, 2285, 2434 and 2680 were scrapped in March 2017, and 2338 is still awaiting its fate.

    References

    New Zealand DSC class locomotive Wikipedia