AshpanA container beneath the furnace, catching ash and clinker that falls through the firebars. This may be made of brickwork for a stationary boiler, or steel sheet for a locomotive. Ashpans are often the location of the damper. They may also be shaped into hoppers, for easy cleaning during disposal.
BlastpipeBlow-downPeriodic venting of water from the boiler. This water contains the most concentrated precursors for sludge build-up, so by venting it whilst still dissolved, the build-up is reduced. When early marine boilers were fed with salt water, they would be blown-down several times an hour.
Blow-down cocka valve mounted low-down on the boiler, often around the foundation ring, which is used for
blow down.
Blowerthe blower provides a forced draught on the fire, encouraging combustion. It consists of a hollow ring mounted either in the base of the chimney or on top of the
blastpipe. Holes are drilled in the top of the blower ring, and when steam is fed into the ring, the steam jets out of the holes and up the chimney, stimulating draught, much like a blastpipe.
BoilerA pressure vessel for the creation of hot water or steam, for residential or commercial use.
Boilersmitha craftsman skilled in the techniques required for the construction and repair of boilers - not to be confused with at
boilermaker (common misconception). A boilermaker is a skilled metalworker, usually the member of a union of the same name, skilled in platework or welding. A boilermaker may or may not be a boilersmith. A boilersmith may also be a member of another trade such as a plumber or pipeworker and so may not be a boilermaker.
Boiler suitheavy-duty one-piece protective clothing, worn when inspecting the inside of a firebox for steam leaks, for which task it is necessary to crawl through the firehole door.
Boiler ticketthe safety certificate issued for a steam (locomotive) boiler on passing a formal inspection after a major rebuild, and generally covering a period of ten years (8 years on the mainline. Additional annual safety inspections must also be undertaken, which may result in the locomotive being withdrawn from service if the boiler requires work. When the ticket "expires" the locomotive cannot be used until the boiler has been overhauled or replaced, and a new ticket obtained.
Boiler water treatmentRemoval or chemical modification of boiler feedwater impurities to avoid scale,
corrosion, or foaming.
Brick archA horizontal baffle of firebrick within the furnace, usually of a locomotive boiler. This forces combustion gases from the front of the furnace to flow further, back over the rest of the furnace, encouraging efficient combustion. The invention of the brick arch, along with the blastpipe and forced draught, was a major factor in allowing early locomotives to begin to burn
coal, rather than
coke.
Bridge clampCarryoverthe damaging condition where water droplets are carried out of the boiler along with the dry steam. These can cause scouring in turbines or hydraulic lock in cylinders. The risk is accentuated by dirty feedwater.See also priming.
Check valveor
clack valve, from the noise it makes. A non-return valve where the feedwater enters the boiler drum. They are usually mounted halfway along the boiler drum, or else as a top feed, but away from the firebox, so as to avoid stressing it with the shock of cold water.
CladdingThe layer of insulation and outer wrapping around a boiler shell, particularly that of a steam locomotive. In early practice this was usually wooden strips held by brass bands. Later and modern practice is to use
asbestos insulation matting (or other less hazardous fibres) covered with rolled steel sheets. The outer shape of the cladding is often a simplification of the underlying boiler shell. Also termed "clothing" in LMS practice.
CrinolinesThe framework of hoops used to support cladding over a boiler. Named from the similar hoops under a
crinoline skirt.
Crown sheetThe upper sheet of the inner firebox on a locomotive boiler. It is the hottest part of the firebox, and sometimes at risk of boiler
explosion, should the water level drop and the crown sheet be exposed and thus allowed to overheat. Supported from above by complex stays.
DamperAn adjustable flap controlling the air admitted
beneath the fire-bed. Usually part of the ashpan.
DisposalThe cleanup process at the end of the working day, usually involving dropping the fire and blowing down the boiler.
Domea raised location on the top of the main boiler drum, providing a high point from which to collect dry steam, reducing the risk of priming.
Downcomerlarge external pipes in many water-tube boilers, carrying unheated cold water from the steam drum down to the water drum as part of the circulation path.
Drowned tubeEither a fire-tube or water-tube that is entirely below the water-level of the operating boiler. As corrosion and scaling is most active in the region of the water-level, this reduces wear and maintenance requirements.
Exhaust injectora feedwater injector that economizes on steam consumption by using waste steam, such as engine exhaust.
FeedwaterFeedwater pumpField-tubeA form of single-ended
thimble water tube with an internal tube to encourage circulation.
FirebarReplaceable cast-iron bars that form the base of the furnace and support the fire. These wear out frequently, so as designed for easy replacement.. See also Rocking grate
FireboxIn a steam engine, the area where the fuel is burned.
FiredoorA door leading from outside the boiler into the firebox, through which fuel (such as coal) could be added by stokers.
Fire droppingEmptying out the remains of the fire after a day's work. A time-consuming and filthy task; labour-saving ways to improve this became important in the final days of steam locomotives.
Fire-tubeFire-tube boilerA boiler where the primary heating surface is tubes with hot gas flowing inside and water outside. . See also water-tube boiler
Flash steamFlueA large fire tube, either used as the main heating surface in a
flued boiler, or used as enlarged firetubes in a locomotive-style boiler where these contain the superheater elements.
Flued boilerFoundation ringThe base of the firebox, where the inner and outer shells are joined.
FurnaceFusible plugA safety device that indicates if the water level becomes dangerously low. It melts when overheated, releasing a jet of steam into the firebox and alerting the crew.
Galloway tubestapered thermic syphon water-tubes inserted in the furnace of a Lancashire boiler.
Gauge glasspart of the water level gauge, which normally consists of a vertical glass tube connected top and bottom to the boiler backplate. The water level must be visible within the glass at all times.
Groovingerosion of a boiler's plates from the internal water space, particularly where there is a step inside the shell. This was a problem for early boilers made from lapped plates rather than butted plates, and gave rise to many
boiler explosions. In later years it was a problem for the non-circular water drums of
Yarrow boilers.
HandholeA small manhole, too small for access but useful for inspection and washing out the boiler. See also mudhole
Injectora feedwater pump without moving parts that uses steam pressure and the Bernoulli effect to force feedwater into the boiler, even against its pressure.
Klinger gauge glassA form of gauge glass where the water level is visible through a flat glass window in a strong metal frame, rather than a cylindrical tube. These were popular with some operators, and increasingly so for high pressure boilers.
Manholean oval access door into a part of the boiler, for example the shell or, in a water tube boiler, the top drum or chamber, large enough for a worker to enter and used for maintenance and cleaning. Manholes are sealed with a removable door from the inside. As they are oval, this door may be turned and lifted out through the hole. Doors are clamped in place from the outside with one or two bridge clamps spanning the hole and tightened down with a nut on a stud. As the cutting of a manhole weakens the boiler shell, the surrounding area is strengthened with a patch.
Muda sludge of boiler scale particles, precipitates and general impurities that builds up in the lower parts of a boiler. Mud reduces water circulation and so a local buildup may lead to localized overheating and possibly explosion.
Mud druma water drum, particularly one mounted low on the boiler whose function is primarily to trap mud from circulation.
MudholeA small manhole, too small for access but useful for washing out the boiler, either as an inlet for a hose or as a drain for removed mud. See also washout plug
PrimingRegulatorRocking grateAn advanced form of firebar, where sections of the grate may be rocked or tipped to either break up clinker within the fire, or to drop the fire after a day's work.
Safety valvean automatic valve used to release excess pressure within the boiler.
Scaledissolved minerals from
hard water that precipitate out in the steam space around the water-level. Where this scale falls to the bottom of the boiler and mixes with other contaminants, it is termed mud.
Scum valveA blow-down valve mounted at the water-level of a boiler, used to blow down lighter oily or foamy deposits within a boiler that float on the water-level.
Sludgeanother term for Mud.
Smokeboxan enclosed space at the extremity of a fire-tube boiler, where the exhaust gases from the tubes are combined and pass to the flue or chimney.
Snifting valveSteam accumulatorSteam druma cylindrical vessel mounted at a high point of a water-tube boiler, where dry steam may separate above the water level, so that it may be drawn off without risk of priming. This is similar to the function of a dome in a fire-tube boiler.
Steam & water druma steam drum that contains a turbulent mixture of steam and water, with a substantial part of this being water. The terms are used somewhat interchangeably.
Steam driera form of mild superheater that adds additional heat to wet- or saturated steam, thus ensuring that all water in the steam has been evaporated, thus avoiding problems with water droplets in the cylinders or
turbine. Unlike the superheater, the steam drier does not attempt to raise the temperature of the steam significantly beyond the boiling point.
Steam generatorSteam separatorSuction valvean automatic non-return valve, which opens when the boiler is at
less than atmospheric pressure. This avoids any risk of vacuum collapse, when a hot boiler is allowed to cool down out of service.
Superheatera device used to convert saturated steam or wet steam into dry steam.
Thermic siphonThree-drum boilerA generic term for water-tube boilers of the Yarrow pattern. In
Royal Navy practice, a reference to the specific Admiralty example of this.
Throatplatea plate forming the lower front of the outer firebox of a locomotive boiler, below the barrel.
Top-feedin locomotive boilers, a feed water check valve placed on the top of the boiler drum. This encourages rapid mixing of the cold feedwater with the hot steam, reducing the risk of thermal shock to the heated parts of the boiler.
Tubeplatea plate across the barrel of a fire-tube boiler, containing many small holes to receive the fire-tubes. A locomotive boiler has two tubeplates: one at the front of the inner firebox (
firebox tubeplate) and one at the front of the boiler, adjacent to the smokebox (
smokebox tubeplate).
Vacuum valveA non-return valve allowing atmospheric air into the boiler, if a cold boiler reduces its internal pressure on cooling down. This avoids the risk of damage to some types, if their pressure loads are reversed. Few boilers are fitted with these, although the feedwater clack valve usually has a similar effect.
Vertical boilerWater-levelWater-walla furnace or other wall within a boiler enclosure that is composed of numerous closely set water-tubes. These tubes may be either bare, or covered by a mineral cement.
Washout plugA small mudhole used for washing out the boiler. Plugs, as compared to mudholes, are usually screwed into a taper thread, rather than held by clamps.
Water drumsee mud drum
Water-tube boilera boiler whose primary heating surface is composed of many small tubes, filled with water. Tubes of 3 inch diameter and above are termed "large-tube" boilers. Later water-tube designs used smaller "small-tubes" of 2 inches or less.
Wet bottom furnace