Cellular confinement systems (CCS)—also known as geocells—are widely used in construction for erosion control, soil stabilization on flat ground and steep slopes, channel protection, and structural reinforcement for load support and earth retention. Typical cellular confinement systems are made with ultrasonically welded high-density polyethylene (HDPE) strips or novel polymeric alloy (NPA)—and expanded on-site to form a honeycomb-like structure—and filled with sand, soil, rock, gravel or concrete.

Contents

History of cellular confinement

Research and development of cellular confinement systems (CCS) began with the U.S. Army Corps of Engineers in 1975 to devise a method for building tactical roads over soft ground. Engineers found that sand-confinement systems performed better than conventional crushed stone sections and they could provide an expedient construction technique for access roads over soft ground, without being adversely affected by wet weather conditions. The US Army Corps of Engineers in Vicksburg, Mississippi (1981) experimented with a number of confining systems, from plastic pipe mats, to slotted aluminum sheets to prefabricated polymeric systems called sand grids and then, cellular confinement systems. Today cellular confinement systems are typically made from strips 50–200 mm wide, ultrasonically welded at intervals along their width. The CCS is folded and shipped to the job site in a collapsed configuration (see picture above).

Efforts for civilian commercialization of the cellular confinement system by the Presto Products Company, led to the Geoweb®. This cellular confinement system was made from high density polyethylene (HDPE), relatively strong, lightweight and suitable for geosynthetic extruding manufacturing. The cellular confinement system was used for load support, slope erosion control and channel lining and earth retention applications in the United States and Canada in the early 1980s.

Research

Early research (Bathurst and Jarrett, 1988) found that cellular confinement reinforced gravel bases are "equivalent to about twice the thickness of unreinforced gravel bases" and that geocells performed better than single sheet reinforcement schemes (geotextiles and geogrids) and were more effective in reducing lateral spreading of infill under loading than conventional reinforced bases. However, Richardson (2004) (who was onsite at the US Corps of Engineers CCS Vicksburg facility) laments 25 years later on the "near absence of research papers on geocells in all of the geosynthetic national and international conferences."

A comprehensive review of available research literature by Yuu, et al (2008) concluded that the use of CCS technology in base reinforcement of paved roads and railways in particular was limited, due to the lack of design methods, lack of advanced research in the last two decades and limited understanding of the reinforcement mechanisms. Fortunately in the last decade research and development in geocell systems expanded significantly. Extensive research has been conducted in recent years on CCS reinforcement for roadway applications at many leading research institutes around the world, to understand the mechanisms and influencing factors of confinement reinforcement, evaluate its effectiveness in improving roadway performance, and develop design methods for roadway applications (Han, et al. 2011).

Extensive research has been conducted in recent years on CCS reinforcement for roadway applications at many leading research institutes around the world, to understand the mechanisms and influencing factors of confinement reinforcement, evaluate its effectiveness in improving roadway performance, and develop design methods for roadway applications.

Han (2013) summarizes comprehensive research conducted at the University of Kansas including static and cyclic plate loading tests, full-scale moving wheel tests, and numerical modeling on geocell-reinforced base courses with different infill materials and discusses the main research findings from these studies regarding permanent, elastic, and creep deformations, stiffness, bearing capacity, and stress distribution, and the development of design methods for geocell-reinforced bases. These studies showed that base courses reinforced with Novel Polymeric Alloy geocells reduced the vertical stresses at the interface between subgrade and base course, reduced permanent and creep deformations, increased elastic deformation, stiffness, and bearing capacity of base courses. Additional literature reviews can be found in Kief et al (2013). and Marto (2013)

Recent innovations in cellular confinement technology

The strength and stiffness of pavement layers determines the performance of highway pavements while aggregate use impacts the cost of duration of installation; therefore alternatives are needed to improve pavement quality using new materials with less aggregate usage (Rajagopal et al 2012). Geocells are recognized as a suitable geosynthetic reinforcement of granular soils to support static and moving wheel loads on roadways, railways and similar applications. But stiffness of the geocells was identified as a key influencing factor for geocell reinforcement, and hence the rigidity of the entire pavement structure.

Utilizing recent advances in polymer and nano technology, extensive R&D was carried out to improve geocell wall stiffness, thermal and elastic properties and long term creep resistance by PRS-Med. The result was a cellular confinement system (PRS-Neoweb) manufactured from Neoloy, a novel polymeric alloy (NPA). NPA is a composite alloy of polyamide nano-fibers dispersed in a polyethylene matrix. It provides ductility similar to HDPE with elastic behavior similar to engineering thermoplastics, to create a stiffer CCS more suitable for heavy duty applications, such as base reinforcement of highways, railways, container yards, etc. that are subject to long-term heavy static and dynamic loading.

Laboratory plate loading tests, full-scale moving wheel tests, and field demonstrations showed that the performance of geocell-reinforced bases depends on the elastic modulus of the geocell. Geocells with a higher elastic modulus had a higher bearing capacity and stiffness of the reinforced base. NPA Geocells showed higher results in ultimate bearing capacity, stiffness, and reinforcement relative to geocells made from HDPE (Pokharel, et al, 2009). NPA geocells showed better creep resistance and better retention of stiffness and creep resistance particularly at elevated temperatures, verified by plate load testing, numerical modeling and full scale trafficking tests (Han, et al. 2011)(Pokharel, et al 2011).

Application vs. long-term performance

CCS have been successfully installed in thousands of projects worldwide. However, it is incumbent to differentiate between low load applications, such as slope and channel applications, and new heavy-duty applications, such as in the base layer of asphalt pavement structures of heavily trafficked motorways and highways. While all polymeric materials used in CCS creep over time and under loading, the question is; what is the rate of degradation, under which conditions, how will this impact performance, and when will it fail?

The lifespan of CCS in slope protection applications, for example, is less critical as vegetative growth and root interlock stabilize the soil. This in effect compensates for any long-term loss of confinement in the CCS. Similarly, load support applications for low volume roads that are not subject to heavy loading usually have a short design life; therefore minor loss of performance is tolerable. However, in critical applications such as reinforcement of the structural layer of asphalt highway pavements, long-term dimensional stability is critical. The required design life for such roads under heavy traffic loads is typically 20–25 years, requiring verifiable long-term durability.

Development of standards for testing CCS

The few standards for CCS were developed more than 40 years ago and have changed little since. Some of the current standards evolved from 2D planar geosynthetics, and as such, do not reflect the composite behavior of 3D geometry of CCS, nor do they test long-term parameters such as: dynamic loading, permanent plastic deformation, effect of temperatures, environmental durability, etc.

On the other hand ISO/ASTM procedures have been developed for testing polymers in the space and automobile industries, as well as for other geosynthetic products. These new standards for CCS were proposed and under discussion by leading experts in geosynthetics in ASTM technical committee D-35. The stated goal is to set new industry standards that more accurately reflect 3D cellular confinement system geometry and material performance in the field rather than lab tests of individual strips and virgin materials that are typically used today. Although international guidelines require the use of the most updated applicable standards, only one geocell manufacturer has done so to date.

An example of one such standard is the SIM - Stepped Isothermal Method (ASTM D-6992) was specifically created for the accelerated creep testing of polymers. This test is important as creep resistance is critical to maintaining confinement, and the functioning of the geocell in the project over time.

How it works

A Cellular Confinement System when infilled with compacted soil creates a new composite entity that possesses enhanced mechanical and geotechnical properties. When the soil contained within a CCS is subjected to pressure, as in the case of a load support application, it causes lateral stresses on perimeter cell walls. The 3D zone of confinement reduces the lateral movement of soil particles while vertical loading on the contained infill results in high lateral stress and resistance on the cell-soil interface. These increase the shear strength of the confined soil, which:

  • Creates a stiff mattress or slab to distribute the load over a wider area
  • Reduces punching of soft soil
  • Increases shear resistance and bearing capacity
  • Decreases deformation
  • Confinement from adjacent cells provides additional resistance against the loaded cell through passive resistance, while lateral expansion of the infill is restricted by high hoop strength. Compaction is maintained by the confinement, resulting in long-term reinforcement.

    On site, the geocell sections are fastened together and placed directly on the subsoil's surface or on a geotextile filter placed on the subgrade surface and propped open in an accordion-like fashion with an external stretcher assembly. The sections expand to an area of several tens of meters and consist of hundreds of individual cells, depending on the section and cell size. They are then filled with various infill materials, such as soil, sand, aggregate or recycled materials and then compacted using vibratory compactors. Surface layers many be of asphalt or unbound gravel materials.

    Roadway load support

    Cellular Confinement Systems (CCS) have been used to improve the performance of both paved and unpaved roads by reinforcing the soil in the subgrade-base interface or within the base course. The effective load distribution of CCS creates a strong, stiff cellular mattress. This 3D mattress reduces vertical differential settlement into soft subgrades, improves shear strength, and enhances load-bearing capacity, while reducing the amount of aggregate material required to extend the service life of roads. As a composite system, cellular confinement strengthens the aggregate infill, thereby simultaneously enabling the use of poorly graded inferior material (e.g. local native soils, quarry waste or recycled materials) for infill as well as reducing the structural support layer thickness. Typical load support applications include reinforcement of base and subbase layers in flexible pavements, including: asphalt pavements; unpaved access, service and haul roads; military roads, railway substructure and ballast confinement; working platforms in intermodal ports; airport runways and aprons, permeable pavements; pipeline road support; green parking facilities and emergency access areas.

    Steep soil slope and channel protection

    The three-dimensional lateral confinement of CCS along with anchoring techniques ensures the long-term stability of slopes using vegetated topsoil, aggregate or concrete surfacing (if exposed to severe mechanical and hydraulic pressures). The enhanced drainage, frictional forces and cell-soil-plant interaction of CCS prevents downslope movement and limits the impact of raindrops, channeling and hydraulic shear stresses. The perforations in the 3D cells allow the passage of water, nutrients and soil organisms. This encourages plant growth and root interlock, which further stabilizes the slope and soil mass, and facilitates landscape rehabilitation. Typical applications include: construction cut and fill slopes and stabilization; road and rail embankments; pipeline stabilization and storage facility berms; quarry and mine site restoration; channel and coastline structures. They can be built as an underlying mass or as a facing.

    Earth retention

    CCS provide steep vertical mechanically stabilized earth structures (either gravity or reinforced walls) for steep faces, walls and irregular topography. Construction of CCS earth retention is simiplified as each layer is structurally sound thereby providing access for equipment and workers, while eliminating the need for concrete formwork and curing. Local soil can be used for infill when suitable and granular, while the outer faces enable a green or tan fascia of the horizontal terraces/rows utilizing topsoil. Walls also can be used for lining channels and in cases of high flow, it is required that the outer cells contain concrete or cementious slurry infill. CCS have been used to reinforce soft or uneven soil foundations for large area footings, for retaining wall strip footings, for load sharing of covers over pipelines and other geotechnical applications.

    Reservoirs and landfills

    CCS provides membrane liner protection, while creating stable soil, berms and slopes, for non-slip protection and durable impoundment of liquids and waste. Infill treatment depends on the contained materials: concrete for ponds and reservoirs; gravel for landfill drainage and leachates, vegetated infill for landscape rehabilitation. Concrete work is efficient and controlled as CCS functions as ready-made forms; CCS with concrete forms a flexible slab that accommodates minor subgrade movement and prevents cracking. In medium and low flow-velocities, CCS with geomembranes and gravel cover can be used to create impermeable channels, thereby eliminating the need for concrete.

    Sustainable construction

    CCS is a green solution that makes civil infrastructure projects more sustainable. In load support applications, by reducing the amount and type of infill needed to reinforce soil, the usage of haul and earthmoving equipment is reduced. This in turn decreases fuel use, pollution and the carbon footprint, and at the same time minimizes on-site disruption from dust, erosion and runoff. When used for slope applications, perforated CCS provides excellent soil protection, water drainage and growth stratum for plants. The long-term design life of advanced CCS technology means that maintenance and the associated environmental costs are significantly reduced, as are long-term economic costs.

    Additional details

  • CCS strip widths, hence the on-site height, come in various sizes from 50 to 300 mm.
  • CCS walls are usually made from textured or structured polymer sheet so as to increase frictional resistance against the infill soil from displacement.
  • CCS are made of HDPE, NPA, low-density polyethylene and nonwoven heat-bonded geotextiles.
  • CCS walls are typically perforated so as to allow for drainage from one cell to another.
  • On steep slopes CCS may have a tendon or cable extending through the central region up the slope and anchored to, or within, a concrete plinth so as to resist downgradient sliding of the system.
  • The backfilling of CCS on long and wide slopes is quite labor-intensive. Construction equipment called phneumatic sand-slingers or stone-slingers have been used advantageously.