Harman Patil (Editor)

Directional control valve

Updated on
Edit
Like
Comment
Share on FacebookTweet on TwitterShare on LinkedInShare on Reddit
Directional control valve

Directional control valves are one of the most fundamental parts in hydraulic machinery as well as pneumatic machinery. They allow fluid flow into different paths from one or more sources. They usually consist of a spool inside a cylinder which is mechanically or electrically controlled. The movement of the spool restricts or permits the flow, thus it controls the fluid flow.

Contents

Nomenclature

The spool (sliding type) consists of lands and grooves.The lands block oil flow through the valve body. The grooves allow oil or gas to flow around the spool and through the valve body. There are two fundamental positions of directional control valve namely normal position where valve returns on removal of actuating force and other is working position which is position of a valve when actuating force is applied. There is another class of valves with 3 or more position that can be spring centered with 2 working position and a normal position.

Classification

Directional control valves can be classified according to-

  • number of ports
  • number of positions
  • actuating methods
  • type of spool.
  • Example: A 5/2 directional control valve would have five ports and two spool positions.

    Ports are the one which helps the liquid to flow through them. Mainly there are 4 ports P-pump, t-tank or oil sump, A&B- flow of liquid to inlet and outlet of tank

    Number of Positions

    Including the normal and working positions which a valve spool can take there are types like two position, three position and proportional valve ...

    Actuating Methods

    Manual, spring, electrical, pneumatic, and hydraulic.

    Manually Operated

    Manually operated valves work with simple levers or paddles where the operator applies force to operate the valve. Spring force is sometimes used to recover the position of valve. Some manual valves utilize either a lever or an external pneumatic or hydraulic signal to return the spool.

    Mechanically Operated

    Mechanically operated valves apply forces by using cams, wheels, rollers, etc., hence these valves are subjected to wear.

    Hydraulically Operated

    A hydraulically operated DCV works at much higher pressures than its pneumatic equivalent. They must therefore be far more robust in nature so are precision machined from higher quality and strength materials.

    Solenoid Operated

    They are widely used in the hydraulics industry. These valves make use of electromechanical solenoids for sliding of the spool. Because simple application of electrical power provides control, these valves are used extensively. However, electrical solenoids cannot generate large forces unless supplied with large amounts of electrical power. Heat generation poses a threat to extended use of these valves when energized over time. Many have a limited duty cycle. This makes their direct acting use commonly limited to low actuating forces.

    Often a low power solenoid valve is used to operate a small hydraulic valve (called the pilot) that starts a flow of fluid that drives a larger hydraulic valve that requires more force.

    A bi-stable pneumatic valve is typically a pilot valve that is a 3 ported 2 position detented valve. The valve retains its position during loss of power, hence the bi-stable name.

    Bi-stability can be accomplished with a mechanical detent and 2 opposing solenoids or a "magna-latch" magnetic latch with a polarity sensitive coil. Positive opens and negative closes or vice versa. The coil is held in position magnetically when actuated.

    Type of Spool

    Spool is of two types namely sliding and rotary. Sliding spool is cylindrical in cross section, and the lands and grooves are also cylindrical. Rotary valves have sphere-like lands and grooves in the form of holes drilled through them.

    Specification

    They are generally specified using the number of ports and the number of switching positions. It can be represented in general form as np/ns, where np is the number of ports connected to the direction control valve and ns the number of switching positions.

    In addition, the method of actuation and the return method can also be specified. A hypothetical valve could be specified as 4-way, 3-position direction control valve or 4/3 DCV since there are four ports and three switching positions for the valve. In this example, one port is called the pressure port which is connected to the pump; one port is the tank port and is connected to the tank (or reservoir); and the two remaining ports are called working ports and are connected to the actuator. Apart from characteristics of valve the fluid suitable for valve,working temperature and viscosity also thought upon before selecting a particular type of valve.

    Symbolic representation

    While working with layouts of hydraulic machinery it is cumbersome to draw actual picture of every valve and other components. Instead of pictures, symbols are used for variety of components in the hydraulic system to highlight the functional aspects. symbol for directional control valve is made of number of square boxes adjacent to each other depending on the number of positions.connections to the valve are shown on these squares by capital letters.usually they are named only in their normal position and not repeated in other positions.actuation system of the valve is also designated in its symbol.

    Two way two position directional control valve

    Gate valve is example of 2W/2P directional control valve which either turns on or off the flow in normal or working positions depending on need of application. Here arrow indicates that fluid flow is taking place whereas other position shows cut-off position.

    Four way two position directional control valve

    4 WAY 2 position valve has four connections to it and two valve positions. One of them is normally open.

    References